The Shenyang Kejing KJML Series Basic Laboratory Heating Plate features a fully enclosed cast steel heating zone design, ensuring enhanced safety by eliminating open flames. It supports stepless temperature adjustment, reaching a maximum temperature of 400°C. It is widely applicable for routine baking, drying, and heating for physical measurements of materials in laboratory settings. Robust, durable, and corrosion-resistant, it serves as an essential piece of foundational equipment for chemistry and materials science laboratories.


In the daily operations of a laboratory, not every heating task requires the precision of advanced digital temperature control. Often, researchers simply require a rugged, durable, fast-heating, and absolutely safe standard heating device for the baking, drying, or high-temperature thermal treatment of samples.


To meet this need, Shenyang Kejing has developed the KJML Series Basic Heating Plate. By eschewing complex settings in favor of ultimate reliability and safety, it has become the preferred choice for routine heating tasks in numerous laboratories.

Laboratory Heating Plate

Core Advantages of the KJML Series Basic Heating Plate

This platform is specifically designed for heating materials that do not undergo drastic changes in properties or physical form during the heating process, distinguishing itself through its exceptional durability and safety-centric design.


1. Fully Enclosed, Open-Flame-Free Design: Prioritizing Safety Above All Else

Laboratory safety is paramount. The KJML Series heating plate features a fully enclosed heating zone design, ensuring that absolutely no open flames are present during operation. This design not only significantly mitigates fire hazards—making the unit safer and more reliable within complex chemical environments—but also minimizes interference to the heating process caused by ambient air currents.


2. Cast Steel Heating Plate with Anti-Corrosion Coating: Built for Harsh Environments

Unlike the stainless steel used in the digital display models, the heating zone of this basic model is constructed from thick cast steel. Cast steel possesses an exceptionally high heat capacity, making it ideal for sustained high-temperature heating applications. Furthermore, its surface has undergone specialized anti-corrosion treatment, while the housing is constructed from high-quality cold-rolled steel treated with an electrostatic powder coating process; this ensures the equipment remains robust and durable, even after prolonged exposure to high temperatures and corrosive chemical reagents. 3. Electronic Stepless Temperature Control and Dual-Phase Power Supply

The device is equipped with an electronic voltage regulator that supports stepless temperature adjustment, offering simple and intuitive operation. Combined with a dual-phase power supply system, the unit delivers rapid heating rates; the maximum heating temperature can easily reach 400°C, thereby satisfying the high-temperature requirements of the vast majority of standard laboratories.


Applications and Product Models

The KJML Basic Heating Platform serves as an ideal solution for baking and drying applications in physical measurements, heat treatment processes, and routine chemical analysis.


We offer three standardized sizes to accommodate various laboratory work surfaces:

- KJML-4028: Dimensions 400 × 280 mm, Power 1500 W

- KJML-4535: Dimensions 450 × 350 mm, Power 2000 W

- KJML-6040: Dimensions 600 × 400 mm, Power 3000 W (Recommended for large-capacity laboratories)


Installation and Environmental Guidelines

To ensure optimal performance and longevity of the equipment, Shenyang Kejing recommends installing and operating this device under the following conditions:

- Ambient Temperature and Humidity: 5–45°C; Relative Humidity 10–85% RH (at 25°C, non-condensing).

- Environmental Safety: Keep away from sources of strong vibration and corrosive gases; maintain a dry, enclosed environment (forced ventilation is not required, but strong air currents blowing directly onto the device should be avoided). 

- Power Requirements: Single-phase AC 220 V / 50 Hz. A standard three-prong grounded plug must be used to ensure proper grounding and safeguard operator safety. 

- Workstation Requirements: It is recommended that the workstation dimensions be no less than 800 × 800 × 700 mm, with a load-bearing capacity of at least 50 kg.


If your laboratory is seeking a basic heating device that offers rapid heating, flame-free operation, durability, and the capability to withstand temperatures up to 400°C, the Shenyang Kejing KJML series is undoubtedly a highly cost-effective choice.


Need detailed specifications or interested in bulk purchasing? Contact your dedicated customer service representative—our product experts are ready at any time to provide you with professional laboratory equipment configuration solutions!


Holen Sie sich den neuesten Preis? Wir werden so schnell wie möglich antworten (innerhalb von 12 Stunden)
This field is required
This field is required
Required and valid email address
This field is required
This field is required
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.